Air
Airflow Performance Data
RF1T/RF1P Series
9
Nominal
Cooling
Capacity
Tons [kW]
Manufacturer
Recommended
Air-Flow Range
(Min/Max) CFM
Blower Size/
Motor
HP [W] &
# of Speeds
Motor
Speed
from
Factory
Motor
Speed
X-13
CFM Dry Delivery/filter/heaters/RPM/Watts
External Static Pressure-Inches W.C.
0.1 [.02]
0.2 [.05]
0.3 [.07] 0.4 [.10] 0.5 [.12]
0.6 [.15]
0.7 [.17]
1.5
852/510
10X6 1/3 Hp
2 speed
dual voltage
5 3
CFM
852 823
792
770 738 713 690
RPM
847 881
915
949
989 1026
1057
Watts
162 151 144 168
182
196
178
5
2
CFM
669
628
593 552 510
RPM
669 713 760 806 852
Watts
80 87
82 94
86
2 973/733
10X6 1/3 Hp
2 speed
dual voltage
5
5
CFM
973
945
922 896 872 852 833
RPM
956 991
1020
1054 1083 1117 1145
Watts
222 221
247
256 253
261
260
5 4
CFM
841
807 780 753
733
RPM
849
890
925 957 992
Watts
160 168 179 187 187
2.5
1145/894
10X8 1/2 Hp
2 speed
dual voltage
5 3
CFM
1145 1122 1084
1064
1055 1025 1002
RPM
767 780
797
820 855
900
954
Watts
240 237 239 245 274 276 306
5 2
CFM
1037
1005
956 924
894
RPM
798
845
901
945
980
Watts
199
213
196
226 237
3
1306/1040
10X8 1/2 Hp
2 speed
dual voltage
5
5
CFM
1306 1268
1223
1195
1162
1128
1093
RPM
887 933
986
1019 1056 1096
1133
Watts
307 313
313 339 373
356
370
5 4
CFM
1201
1163 1129
1094 1065
1040
RPM
866
914
964 999 1032
Watts
278 286
301
324 348
208V/240V Airflow Performance Data—RF1T (X-13 (ECM) Motor)
Notes: X-13 motor speed changes.
All X-13 motors have 5 speed taps. Speed tap 1 is for continuous fan. Speed tap 2 (low static) and speed tap 3 (high static) are for lower tonnage. Speed tap 4 (low
static) and speed tap 5 (high static) are for higher tonnage.
X-13 air handlers are always shipped from factory at speed tap 5. To change to 1.5-ton or 2.5-ton airflow, move the blue wire to speed tap 2 or 3 on the
X-13 motor. The low static speed tap 2 (lower tonnage) and 4 (higher tonnage) are used for external static below 0.5" WC. The high static speed tap 3 (lower tonnage)
and 5 (higher tonnage) are used for external static exceeding 0.5" WC. Move the blue wire to the appropriate speed tap as required by the application needs.
The airflow for continuous fan (speed tap 1) is 50% of the speed tap 4 airflow.
The above airflow table lists the airflow information for air handlers with maximum heater allowed for each model.
[ ] Designates Metric Conversions