
Humidification System
15 69-2307—01
Loosen captive cover
screw. Slide cover out from
front.
11
WIRIng
CAUTION: Voltage Hazard.
Before wiring to HVAC terminals, disconnect HVAC
equipmentpower.Ensurehumidifierisnotpluggedin.
Low-Voltage Terminals
24V AC power for electronic humidistat.
HUM Low-voltage humidistat (or thermostat) terminals control
humidifier operation.
C, R Connects to HVAC system transformer terminals (or relay
transformer fan control R and C) to ensure HVAC power
is present before humidifying. This can be disabled by
changing DIP switch 4 (see page 18).
RT Connects to thermostat R terminal, which is normally
switched to call for fan.
GT, GT connects to thermostat G terminal. GF connects
to fan board G terminal. Thermostat G passes through
the normally-closed (NC) relay contacts to GF, allowing
fan activation. When the humidifier is ready to provide
humidity to the home, it will take control of the fan by
forcing power from RT to GF (if not already activated).
EXT Whena24-vacfanboardisnotusedtocontrolblower
(hydronic or cooling-only applications), this connection
withGFprovidesdry-contactclosureforfancalls.EXT/
GF may be wired to a low-voltage relay control center to
provide line-voltage fan control.
M24895
24V
24V
HUM
HUM
C
GT
R
RT
GF
EXT
GF
Route wires through the raised harness tabs and out the notch at
therearofthechassis.Ensurewiresaresecureanddonotinter-
fere with assembly of cover.
Tabs Notch
PlumbIng
Comentarios a estos manuales