Rheem Heating, Cooling and Water Heating 7
External Static Pressure-Inches W.C. [kPa]
PSC CFM wet coil with filter and heaters
RPM 1083
Blower Size/
Motor
HP [W]
# of Speeds
1090
Motor
Speed
1096
Manufacturer
Recommended
Air-Flow Range
(Min/Max) CFM
Motor
Speed
From
Factory
1101 1109 1114 1121
Watts 380 365 360 349 338 328 311
10x6
1/5 HP [149]
2 Speed
Dual Voltage
CFM 830 [425] 805 [425] 772 [425] 735 [425] 690 [425]
RPM
0.1 [.02] 0.2 [.05] 0.3 [.07] 0.4 [.10] 0.5 [.12] 0.6 [.15] 0.7 [.17]
932 950 974 994 1014
RPM 948 970 989 1003 1021 1037 1046
Nominal
Cooling
Capacity
Tons
2
2.5
3
1.5
Watts 269 262 252 245 238 226 221
10x6
1/5 HP [149]
2 Speed
Dual Voltage
Low
1016/690 CFM
[479/326 L/s]
CFM 642 [271] 606 [260] 575 [366] 521 [366] 450 [366]
High
CFM 1016 [389] 966 [389] 927 [389] 885 [389]
RPM 766 798 817 864 912
834 [413] 780 [425] 718 [425]
Watts 270 262 253 244 235
RPM 900 927 950 974 997 1018 1038
Watts 374 361 346 331 320 307 290
10x8
1/4 HP [186]
2 Speed
Dual Voltage
CFM 1034 [566] 983 [555] 931 [555] 868 [566] 808 [578]
RPM 836 860 892 921 944
Low
1190/808 CFM
[562/381 L/s]
High
CFM 1190 [566] 1116 [566] 1058 [578] 997 [578] 927 [566] 851 [566] 762 [566]
Watts
300 291 281 269 260
RPM 1029 1047 1060 1082 1095 1104
Watts 478 456 437 403 376 355
10x8
1/3 HP [186]
2 Speed
Dual Voltage
CFM 1189 [791] 1135 [779] 1054 [779] 976 [767]
RPM 958 984 1012 1037
High
1330/976 CFM
[628/461 L/s]
High
CFM 1330 [566] 1262 [566] 1184 [767] 1066 [779] 968 [779] 871 [779]
Watts 402 385 362 341
Low
850/450 CFM
[401/212 L/s]
High
CFM 850 [260] 807 [271] 763 [283] 723 [283] 644 [295] 568 [295] 538 [295]
Watts
175 170 168 158 149
High
Low
High
High
208V/240V Airflow Performance Data—RHAL (PSC Motor)
Notes: • All 208/240V PSC motors have voltage taps for 208 and 240 volts.
• All 208/240V PSC motors are shipped on high speed and 240 volts.
• If the application external static is less than 0.5" WC, adjust the motor speed to the low static speed as described below:
• Unplug the black motor wire off the relay on the control board and plug in the red motor wire.
• Replace the cap on the black motor wire.
• Voltage change (208/240V motors):
• Move the orange lead to transformer 208V tap from 240V tap. Replace the wire cap on 240V tap.
• Unplug the purple motor wire off the transformer and plug in the yellow motor wire.
• Replace the cap on the purple motor wire.
• The above airflow table lists the airflow information for air handlers with maximum heater allowed for each model.
[ ] Designates Metric Conversions