16.0
Rheem Value Series
Air Conditioners
FORM NO. A11-218 REV. 1
13A(-)N- Series
Efficiencies up to 14.5 SEER/12 EER
Nominal Sizes 1.5-5 Ton [5.28 to 17.6 kW]
Cooling Capacities 16.6 to 58 kBTU
[4.86 to 17.0 kW]
Outdoor air conditioner designed for ground level or rooftop
installations. These units offer comfort and dependability for
single, multi-family and light commercial applications.
Painted louvered steel cabinet
Easily accessible control box
Condenser coils constructed with copper tubing and
enhanced aluminum fins.
Grille/Motor mount for quiet fan operation
Filter Drier (shipped – not installed)
Air
Air Conditioners
13A(-)N Series
“Proper sizing and installation of equipment is critical to achieve
optimal performance. Ask your Contractor for details or visit
www.energystar.gov.”
Vista de pagina 0
1 2 3 4 5 6 ... 27 28

Indice de contenidos

Pagina 1 - Air Conditioners

16.0Rheem Value SeriesAir ConditionersFORM NO. A11-218 REV. 113A(-)N- SeriesEfficiencies up to 14.5 SEER/12 EERNominal Sizes 1.5-5 Ton [5.28 to 17.6 k

Pagina 2 - TABLE OF CONTENTS

AirPerformance Data13A(-)N Series10Performance Data @ AHRI Standard Conditions—CoolingModel Numbers80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air95°F [3

Pagina 3 - Model Features:

AirPerformance Data13A(-)N Series11Performance Data @ AHRI Standard Conditions—CoolingModel Numbers80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air95°F [3

Pagina 4 - 200-Series *

AirPerformance Data13A(-)N Series12Performance Data @ AHRI Standard Conditions—CoolingModel Numbers80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air95°F [3

Pagina 5

AirPerformance Data13A(-)N Series13Performance Data @ AHRI Standard Conditions—CoolingModel Numbers80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air95°F [3

Pagina 6

AirPerformance Data13A(-)N Series14Performance Data @ AHRI Standard Conditions—CoolingModel Numbers80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air95°F [3

Pagina 7

AirPerformance Data13A(-)N Series15Performance Data @ AHRI Standard Conditions—CoolingModel Numbers80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air95°F [3

Pagina 8

AirPerformance Data13A(-)N Series16Performance Data @ AHRI Standard Conditions—CoolingModel Numbers80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air95°F [3

Pagina 9

AirPerformance Data13A(-)N Series17Performance Data @ AHRI Standard Conditions—CoolingModel Numbers80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air95°F [3

Pagina 10 - 13A(-)N Series

AirPerformance Data13A(-)N Series18Performance Data @ AHRI Standard Conditions—CoolingModel Numbers80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air95°F [3

Pagina 11

AirPerformance Data13A(-)N Series19Performance Data @ AHRI Standard Conditions—CoolingModel Numbers80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air95°F [3

Pagina 12

AirTable of Contents13A(-)N Series2TABLE OF CONTENTSModel Features ...

Pagina 13

AirPerformance Data13A(-)N Series20Performance Data @ AHRI Standard Conditions—CoolingModel Numbers80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air95°F [3

Pagina 14

21AirPerformance Data13A(-)N SeriesPerformance Data @ AHRI Standard Conditions—CoolingModel Numbers80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air95°F [3

Pagina 15

AirElectrical and Physical Data13A(-)N Series22ModelNumber13AJNELECTRICAL PHYSICALPhaseFrequency (Hz)Voltage (Volts)CompressorFan MotorFull LoadAmpere

Pagina 16

AirUnit Dimensions13A(-)N Series23Unit DimensionsModel No.13A(-)NUnit Dimensions60 315/8 [803] 315/8 [803]Width “W”Inches Length “L”Inches Height “H”I

Pagina 17

AirRefrigerant Line Size Information13A(-)N Series24Suction Line Length/Size versus Capacity Multiplier (R-410A)Unit Size 11/2 Ton 2 Ton 21/2 Ton 3 To

Pagina 18

AirLimited Warranty13A(-)N Series25GENERAL TERMS OF LIMITED WARRANTY*Rheem will furnish a replacement for any part of this productwhich fails in norma

Pagina 19

AirNotes13A(-)N Series26

Pagina 20

AirNotes13A(-)N Series27

Pagina 21

The new degree of comfort.™Rheem Heating, Cooling & Water Heating • P.O. Box 17010 Fort Smith, Arkansas 72917 • www.rheem.com In keeping with

Pagina 22 - Electrical and Physical Data

AirModel Features13A(-)N Series3Model Features: Outdoor condensing unit designed for ground level or rooftopinstallations. These units offer comfort

Pagina 23 - Unit Dimensions

AirModel I.D./Accessories/Compressor13A(-)N Series4Model Number Identification13 A * N 18NOMINAL COOLING CAPACITY18 = 18,000 BTU/HR [5.28 kW]24 = 24

Pagina 24

AirPerformance Data13A(-)N Series5Performance Data @ AHRI Standard Conditions—CoolingModel Numbers80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air95°F [35

Pagina 25

AirPerformance Data13A(-)N Series6Performance Data @ AHRI Standard Conditions—CoolingModel Numbers80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air95°F [35

Pagina 26

AirPerformance Data13A(-)N Series7Performance Data @ AHRI Standard Conditions—CoolingModel Numbers80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air95°F [35

Pagina 27

AirPerformance Data13A(-)N Series8Performance Data @ AHRI Standard Conditions—CoolingModel Numbers80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air95°F [35

Pagina 28 - The new degree of comfort

AirPerformance Data13A(-)N Series9Performance Data @ AHRI Standard Conditions—CoolingModel Numbers80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air95°F [35

Comentarios a estos manuales

Sin comentarios